Method 17 provides in-stack filtration of particulate and eliminates the requirement of the
Method 5 heated filter box. Our PRI-TO Stainless Steel Thimble Filter Holder, used for high
particulate loading, holds both 30mm x 100mm glass fiber thimbles and 34mm x 100mm
Alundum thimbles. The PRI-T-P Pyrex Thimble Filter Holder holds 30mm x 100mm Glass or
Quartz fiber thimbles and is predominantly used in applications where it is prohibited to have
metal in the sample pathway. Our GFS-2-10 Stainless Steel 47mm Filter Holder holds flat 47mm
diameter glass fiber filter paper and is for low particulate loading applications. Both filter
holders have 5/8″ union fittings on inlet and outlet ends for fastening directly between the
nozzle and probe sheath.
A Method 17 sampling train can be set up with an isolated probe and flexible heated or unheated
sample transfer line to the impingers, or with the probe directly linked to the impinger set using
our probe support adapter panel mounted to the impinger box.